F74G General Purpose Filters
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-1-9
Technical Data
Fluid: Compressed air
Maximum pressure
Transparent bowl: 150 psig (10 bar)
Metal bowl: 250 psig (17 bar)
Operating temperature*:
Transparent bowl: -34° to 125°F (-30° to 50°C)
Metal bowl: -34° to 175°F (-30° to 80°C)
* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Particle removal: 5, 25, or 40 µm filter element
Air quality: Within ISO 8573-1, Class 3 and Class 5 (particulates)
Typical flow with a 40 µm element at 90 psig (6.3 bar) inlet pressure and 5 psig
(0.35 bar) pressure drop: 140 scfm (66 dm
3
/s)
Manual drain connection: Will fit 1/8-27 and 1/8-28 pipe thread
Automatic drain connection: Will fit 1/8-27 and 1/8-28 pipe thread. - Flexible tube
with 3/16" (5mm) minimum I.D. can be connected to the automatic drain. Drain
may fail to operate if the tube I.D. is less than 3/16" (5mm). Avoid restrictions in
the tube.
Automatic drain operating conditions (float operated):
Bowl pressure required to close drain: Greater than 5 psig (0.3 bar)
Bowl pressure required to open drain: Less than 3 psig (0.2 bar)
Minimum air flow required to close drain: 2 scfm (1 dm
3
/s)
Manual operation: Depress pin inside drain outlet to drain bowl
Nominal bowl size: 7 fluid ounce (0.2 liter)
Materials
Body: Aluminum
Bowl
Transparent: Polycarbonate with steel bowl guard
Metal: Aluminum
Metal bowl liquid level indicator lens: Transparent nylon
Element: Sintered polypropylene
Elastomers: Neoprene and Nitrile
An automatic drain is a two-way valve, which will close when the system is
pressurized. The drain opens when the float rises due to accumulated liquid
and on depressurization.
Typical Performance Characteristics
* Minimum clearance required to remove bowl.
† Dimension for alternative electrical service indicator is 1.98" (50.4 mm)
Item
Type Part Number
Service kit Seal & gasket 4380-700
Replacement elements
5 µm 4338-04
25 µm 4338-07
40 µm 4338-05
Liquid level lens kit Prismatic 4380-050
Replacement drains
Automatic (1/8 NPT outlet) 3000-10
Manual quarter turn 619-50
Service kit includes louvre/element seal, drain seal, bowl seal.
Service Kits
All Dimensions in Inches (mm)