F64G General Purpose Filters
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-1-11
Technical Data
Fluid: Compressed air
Maximum pressure
Guarded transparent bowl: 150 psig (10 bar)
Metal bowl: 250 psig (17 bar)
Operating temperature*:
Guarded transparent bowl: -30° to 125°F (-34° to 50°C)
Metal bowl: -30° to 175°F (-34° to 80°C)
* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Partical removal: 5 µm, 25 µm or 40 µm. Within ISO 8573-1, Class 3 and Class 5
Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and 5 psig
(0.35 bar) pressure drop: 125 scfm (59 dm
3
/s)
Manual drain connection: Will fit 1/8-27 and 1/8-28 pipe thread.
Automatic drain connection: Will fit 1/8-27 and 1/8-28 pipe thread. - Flexible tube
with 3/16" (5mm) minimum I.D. can be connected to the automatic drain. Drain
may fail to operate if the tube I.D. is less than 3/16" (5mm). Avoid restrictions in
the tube.
Automatic drain operating conditions (float operated):
Bowl pressure required to close drain: Greater than 5 psig (0.3 bar)
Bowl pressure required to open drain: Less than 3 psig (0.2 bar)
Minimum air flow required to close drain: 2 scfm (1 dm
3
/s)
Manual operation: Depress pin inside drain outlet to drain bowl
Nominal bowl size: 7 fluid ounce (0.2 liter)
Materials
Body: Zinc
Yoke: Zinc
Metal bowl: Aluminum
Standard metal bowl prismatic liquid level indicator lens: Grilamid
Optional metal bowl sight glass: Pyrex
Optional transparent bowl: Polycarbonate
Element: Polypropylene
Elastomers: Nitrile
An automatic drain is a two-way valve, which will close when the system is
pressurized. The drain opens when the float rises due to accumulated liquid
and on depressurization.